customer id number -> KING_0269
connectivity -> wired -> static ip
-> backoffice -> standalone <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<
authorization -> authorization mode -> plug & charge
-> plug & charge id -> KING_0629
power settings -> installation -> station max current -> 16
-> connector 1 -> 16
load balancing -> active balancing -> active load balancing -> on
-> data source -> meter <<<<<<<<<<<<<<
-> protocol selection -> modbus tcp/ip
-> max smart meter current -> 25 <<<<< max amperes provided by the provider
-> allow single/multiphase charging -> on
-> tcp/ip meter -> ip address -> 10.1.1.51
-> slave address -> 1
-> mode -> custom register mapping
-> custom register mapping
Current L1 40072 signed16 x0,001
Current L2 40073 signed16 x0,001
Current L3 40074 signed16 x0,001
Real Power L1 40088 signed16 x1
Real Power L2 40089 signed16 x1
Real Power L3 40090 signed16 x1