1. Eve Single Pro-line

        name: KING_0269
       model: NG910-60027
objectnumber: ACE0166269
       firmw: 5.8.1-4123 -> 6.6.2-4312 ->  7.0.5-4328 -> 7.1.3-4342 -> 7.1.6-4345
         lic: 2580.7501.8911.0600.785D.E80F -> 5C80.0101.2601.4101.175F.AE90
      ipaddr: 10.1.1.81
     macaddr: 32:67:4d:74:62:51

2. upm

userid: Post
passwd: prEze8
 owner: EnergyKing1

3. factory reset

customer id number -> KING_0269

connectivity -> wired -> static ip
             -> backoffice -> standalone <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<

authorization -> authorization mode -> plug & charge
              -> plug & charge id -> KING_0629

power settings -> installation -> station max current -> 16
               -> connector 1 -> 16

load balancing -> active balancing -> active load balancing -> on
                                   -> data source -> meter <<<<<<<<<<<<<<
                                   -> protocol selection -> modbus tcp/ip
                                   -> max smart meter current -> 25 <<<<< max amperes provided by the provider
                                   -> allow single/multiphase charging -> on

               -> tcp/ip meter -> ip address -> 10.1.1.51
                               -> slave address -> 1
                               -> mode -> custom register mapping

                               -> custom register mapping

Current L1          40072       signed16        x0,001
Current L2          40073       signed16        x0,001
Current L3          40074       signed16        x0,001

Real Power L1   40088   signed16        x1
Real Power L2   40089   signed16        x1
Real Power L3   40090   signed16        x1